M-2008 PRO Pull-Out Tester
Hydraulic pull-out testing device for medium to large loads — proof-loads dowels, mechanical anchors, chemical anchoring and rebar installed with chemical adhesive, right on the job site. Supplied as a heavy-duty kit in a carrying case.
The Adit pull-out testing family
Choose the right on-site testing device for your load range and application.
Technical specification
| Property | M-2008 PRO — heavy-duty pull-out tester |
|---|---|
| Device type | Hydraulic pull-out (bond) tester |
| Load capacity | Up to 125 kN |
| Tested elements | Dowels and anchors for medium to heavy loads; chemical anchoring and rebar installed with chemical adhesive |
| Load range | Medium to heavy loads |
| Application | On-site proof and pull-out testing |
| Supplied as | Heavy-duty kit in a carrying case |
Downloads
On-site pull-out testing: the complete guide
Everything you need to know about on-site pull-out testing of anchors and post-installed rebar — from why it is done, through how the M-2008 PRO device works, to reading the results. This guide was written by the experts at Adit Ltd., the largest chemical-anchor company in Israel.
What is a pull-out test and why does it matter?
A pull-out test (also called a proof or bond test) applies a controlled tensile force to an installed anchor, dowel or rebar and measures how the element behaves under that load. It is the practical way to confirm, in the field, that an anchor has been installed correctly and that the base material carries the intended load.
On-site testing is especially important for chemical anchoring and for rebar planted with chemical adhesive, where the strength of the connection depends on correct drilling, thorough hole cleaning and proper injection. A pull-out test turns those installation steps into a measured, documented result.
Proof load versus load to failure
Most site testing is proof testing: the anchor is loaded up to a defined proof value and held, to verify it does not move or fail. In a laboratory or a qualification programme, elements may instead be pulled all the way to failure to establish their ultimate capacity. The M-2008 PRO covers the medium-to-heavy load range with a capacity of up to 125 kN.
How the M-2008 PRO works
- Set up over the anchor — position the bridge of the device so the hydraulic ram is centred and aligned with the axis of the anchor or rebar being tested.
- Connect the element — couple the tested dowel, anchor or rebar to the device using the matching adaptor from the kit.
- Apply load — increase the hydraulic force gradually and steadily up to the required test load, watching the gauge.
- Read and record — record the load reached and whether the element held, moved or failed, and keep the reading for the project documentation.
- Release and pack — release the pressure, disconnect and return the components to the carrying case.
What the M-2008 PRO tests
- Dowels and mechanical anchors for medium to heavy loads.
- Chemical anchoring — threaded rods and bolts set with chemical adhesive.
- Post-installed rebar planted with chemical adhesive.
Why choose Adit Ltd. for your testing equipment?
In a market full of anchoring products and tools, choosing the right supplier is just as important as choosing the device. Adit Ltd. — the largest company in the field in Israel today — offers a complete package:
- In-depth engineering support: engineers who help define the correct proof load for your anchor type and load case.
- Field training: agents with over 10 years of experience come to the site and show correct testing procedure.
- Complete kits: the device is supplied with the adaptors needed for the medium-to-heavy load range in a carrying case.
- Available immediate stock: fast supply to any point in the country from the largest warehouse in Israel.
Frequently asked questions
What load can the M-2008 PRO reach?
Which elements can be tested with the device?
Is this a proof test or a test to failure?
Is the device portable?
How do I choose between the M-2000 PRO and the M-2008 PRO?
Need to verify anchors or rebar on site? Tell us the anchor type, diameter and required test load — our engineers will advise on the right device and testing procedure.